I noticed that if I run the bed for the full session and try and put it on for another session right after (within 5 min) the face tanners don't turn on. It's weird, sometimes 1 face tanner comes on or sometimes 2 or 3 and sometimes none of them come on. I should mention that all of the tubes come on as usual. This only happens if I run the bed back to back (within 5 min of a previuos session) This hasn't happened yet when the sessions are spaced out. Is there some sort of timer that prevents them from turning on? It doesn't make sense though as it seems to be different face tanners that are not working or none at all when this does happen. Can anyone help?
|
|
|
|
|
|
#2 (permalink) |
![]() Join Date: Aug 27 2002
Location: East Coast
Posts: 371
Rep Power: 7
![]() |
Re: '03 Sunstorm face tanners not turning on?
They are either not getting cooled enough caused by a weak fan or your voltage is low. When HP lamps are hot they do not light. This is made worse when the volatge is low.
What is your voltage inside the bed at the main power connection? What brand of HP lamps are you burning? How many hours on the HP lamps? How long do your fans run after a session ends?
__________________
Robert Klem Superior UV Technologies |
|
|
|
|
|
#3 (permalink) | |
![]() Join Date: Dec 18 2007
Posts: 42
Rep Power: 0
![]() |
Re: '03 Sunstorm face tanners not turning on?
Quote:
Heraeus low, maybe 40hrs just relamped fans run for 5 min after session ends |
|
|
|
|
|
|
#4 (permalink) |
![]() Join Date: Aug 27 2002
Location: East Coast
Posts: 371
Rep Power: 7
![]() |
Re: '03 Sunstorm face tanners not turning on?
You should go up around 240v. Is that 232v running or 232v with no load? It may drop to below 230v when running and that maybe the issue with Heraeus lamps.
The unit came with Radium lamps which start better.
__________________
Robert Klem Superior UV Technologies |
|
|
|
|
|
#6 (permalink) |
|
I vote for DERF!
![]() Join Date: Jan 6 2004
Location: Midwest-ish
Posts: 2,649
Rep Power: 5
![]() ![]() ![]() ![]() |
Re: '03 Sunstorm face tanners not turning on?
THe Heraeus lamps I have run hot. If the bed has individual thermal couplers like mine, then there is a cooling issue or an ignitor is on its way out. For me its usually and ignitor that wont fire when the bed gets too many back to back sessions, but when cool its fine. Replace ignitor and all is fine.
As for fans, some can even spin and this look like they are working when they are not. Its just air flow caused by other fans. So pay close attention when checking fans.
__________________
"It’s hard to believe how or why, but there really exists a subculture in America that is militaristic, hateful, vengeful, irrational and ambitious. These extremists are cancerous to progressive society and similar groups have had similar effect throughout the history of civilization. America’s version of the Taliban consists of fundamentalist Christians and their cult-like behavior."
|
|
|
|
|
|
#7 (permalink) |
![]() Join Date: Aug 27 2002
Location: East Coast
Posts: 371
Rep Power: 7
![]() |
Re: '03 Sunstorm face tanners not turning on?
SunStorms do not have facial fans. They feature 1 main fan for the whole bed. The fan may be the issue but more likely the running voltage may be low.
Since there are issues on all the lamps it would most likely not be all the ignitors. I would first check the running voltage. Do not run the bed for more then a minute with the front cover off when checking the voltage. If the Voltage is below 230v I would boost the voltage. The ballasts for those facials are rate at 250v.
__________________
Robert Klem Superior UV Technologies |
|
|
|
|
|
#8 (permalink) | |
![]() Join Date: Dec 18 2007
Posts: 42
Rep Power: 0
![]() |
Re: '03 Sunstorm face tanners not turning on?
Quote:
|
|
|
|
|
|
|
#9 (permalink) |
![]() Join Date: Aug 27 2002
Location: East Coast
Posts: 371
Rep Power: 7
![]() |
Re: '03 Sunstorm face tanners not turning on?
It is normal for voltage to drop a volt or two when a bed is running. Sometimes it drops 3-4 volts which may put you under 230 volts when running. Orbits / Sunstorms love voltage. Feed it around 240 and watch you clients tan!
.....and your facials turn on! .....and buy some Radium facials for a real blast!
__________________
Robert Klem Superior UV Technologies |
|
|
|
|
|
#10 (permalink) |
![]() Join Date: Mar 30 2006
Location: Los Angeles
Posts: 89
Rep Power: 0
![]() |
Re: '03 Sunstorm face tanners not turning on?
remove the front kick plate you will see a vent with a cage in the middle make sure you remove all the lint and crap there with a vacuum. next check the vent covers on the back of the unit one on the foot and one at the head end,make sure both are intact and not broken your issue sounds like a heat problem . if the voltage is above 220 is should light up the facials. no more that 235v if you do the life of the bulbs will be reduced. over 240 and these beds tan like no other but reduce life of bulbs. call me if you need more help 3104181519
__________________
California Tanning Bed Technician 310-418-1519 |
|
|
|
![]() |
| Bookmarks |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Non-Face Tanners | kimiek8692 | Open Forum | 14 | 05-26-2006 02:51 PM |
| 2 Sun Dash 232 w/o Face Tanners | In2Tanning | For Sale | 3 | 04-22-2005 10:14 AM |
| Does anyone have face tanners? | sandstan | Salon Management | 13 | 10-26-2004 08:42 PM |
| face tanners | summerbreeze | Open Forum | 7 | 05-29-2004 12:29 AM |
| face tanners | jlynnh73 | Equipment | 9 | 05-26-2001 09:27 PM |